Q series four-way output Q-6060W four groups of switching power supply

Q series four-way output Q-6060W four groups of switching power supply

产品概述:Technical parameters: project Q-60BQ-60CQ-60D output output channel CH1CH2CH3CH4CH1CH2CH3CH4CH1CH2CH3CH4 DC voltage 5V12V-5V-12V5V15V-5V-15V5V12V24V-12V rated c···

产品简介

technical parameter:

projectQ-60BQ-60CQ-60D
outputoutput channelCH1CH2CH3CH4CH1CH2CH3CH4CH1CH2CH3CH4
DC voltage                           5V12V-5V-12V5V15V-5V-15V5V12V24V-12V
Rated current5A2A0.5A0.5A5A1.5A0.5A0.5A3A1A1A0.5A
Current range0.5-6A0.2-3A0-1A0-1A0.5-6A0.2-2A0-1A0-1A0.5-4A0.2-1.5A0.1-1A0-1A
rated power57.5W57.5W57W
Ripple and Noise①80mV120mV100mV120mV80mV120mV100mV120mV80mV120mV150mV120mV
Voltage accuracy±2%±6%±3%±3%±2%±6%±3%±3%±2%±6%+7, -5%±3%
Output voltage regulation rangeCH1: ±10% 
Load Regulation ±0.5%±3.0%±1.0%±1.0% ±0.5%±3.0%±1.0%±1.0% ±0.5%±3.0%±3.0%±1.0% 
Linear adjustment rate ±0.5% ±1.5% ±0.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±0.5% ±1.5% ±2.0% ±0.5% 
entervoltage range85-264VAC 47Hz~63Hz (254VDC~370VDC)
Efficiency (Typical) ②>78%>78%>80%
Working current<1.1A 110VAC <0.6A 220VAC
electric shock110VAC 18A, 220VAC 45A
Start, rise, hold time900ms, 20ms, 20ms: 220VAC/800ms, 20ms, 10ms: 115VAC
ProtectOverload protection     105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on
Short circuit protection +VO drops to the undervoltage point to turn off the output 
surroundingsWorking temperature and humidity-10℃~+50℃; 20%~90RH
Storage temperature and humidity-20℃~+85℃; 10%~95RH
SafetyWithstand voltage Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute                                     
leakage currentInput-output <5mA at 1.5KVAC
leakage currentInput-output <2mA at 240VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize159*98*38mm
Net weight/gross weight440/470g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth.

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃.

Accuracy: including setting error, linear regulation and load regulation

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load. 

The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters.



Excel Energy Co., Ltd.